Хайх үгээ оруулна уу..

Low Voltage Soft Starters: iStart


Ratings: 17-1100A, 208-690V
The iStart is Solcon’s latest, most advanced digital soft starter, with built-in bypass and 2 or 3 phase control.
It incorporates enhanced soft-start and soft-stop characteristics providing the best solution for a wide range of applications.

The comprehensive motor protection package guarantees long term reliability while the built-in bypass ensures excellent performance, all in a small, versatile design.

istart-breakout

Solcon’s Flagship Low Voltage Soft Starter

Solcon’s new video allows you to discover the perfect low voltage starter and shows you the construction and capabilities of the iStart.

The iStart enhanced soft-start and soft-stop characteristics provide the best solution for most applications. The comprehensive motor protection package guarantees long term reliability while the built-in bypass ensures excellent performance, all in a small footprint design.

Advanced Features

  • State of the art communication options
  • Multi-language operating system
  • Real-time, online 99 event log and trip log (including currents, voltages)
  • Optimized for high efficiency motors (IE3)
  • 2-phase mode for on-site phase fault operation
  • Plug and play fan option for increased capacity (sizes A, B, C)
  • Basic, professional and expert set-up menus
  • User defined metering and monitoring of 3-phase voltage, 3-phase current and power factor
  • Auto reset for selected faults
  • 3 Thermistor inputs available
  • Frequency autotracking 45-65 Hz
  • Inline and inside delta connection
  • Universal control voltage 110-220 V AC/DC (sizes A, B, C)
  • 3 Current transformers

Typical Applications

  • Pumps (Water utilities, Industry)
  • Compressors
  • Conveyors & monorails
  • Mixers & Agitators
  • Fans & Centrifuges
  • Hydraulic pumps
  • Starting from weak power sources

iStart-control

iStart protection

  • Under voltage
  • Phase sequence
  • Shear pin current
  • Under current
  • Overload classes
  • Current imbalance
  • Ground fault
  • Excessive number of starts
  • Excessive starting time
  • Soft starter over temperature
  • Programmable external fault
  • Phase loss
  • Communication network timeout or failure
  • Inside delta wrong connection alarm

Soft start & soft stop

  • Acceleration control
  • Current limit start
  • 5 Application Adjustments: 3 pump curves, generator and torque control
  • Kick start
  • Restart delay (3 seconds)

Partner Organizations